Frequency
(Hz)
Calculated Values
Measured Values

(dB)
V0(mV)
Vsh(mV)
A(dB)
V0(mV)
Vsh(mV)
A(dB)
50
15.7
14.5
0.7
15.2
12.4
1.8
–1.1
100
31.4
26.3
1.5
30.9
21.8
3.0
–1.5
200
62.8
40.4
3.8
62.4
32.8
5.6
–1.8
300
94.3
47.0
6.0
94.0
38.6
7.7
–1.7
500
157
52.5
9.5
156
44.0
11.5
–2.0
1000
314
56.6
14.9
315
48.2
16.3
–1.4
Table I. A comparison of mathematical calculations from the circuit model and experimental results achieved with a device design based on the model, with signifying the difference by which the measured attenuation betters the calculated values. Return to Main Article