| Test
levels are given as the maximum or range of generator open circuit ac voltages,
ac frequency, test time, and the value or values of the current limit resistor. Note 1: Not applied to equipment designs to be always used with primary protection. K.20 and K.21 equipment also need operator agreement. Note 2: Equipment containing high-current-carrying components that eliminate the need for primary protection shall be tested without primary protection. Equipment shall use special worst-case high-current-carrying components. Note 3: To suit local conditions, a voltage of 300 V rms 3⁄4 V 3⁄4 600 V rms and time t 3⁄4 1.0 sec may be specified. The series current limit resistance shall then be R = V(t).0.5 Note 4: All voltage-time combinations shall be tested as defined by the time equation. Note 5: Equipment that is always used with primary protection shall be tested with a special agreed primary protector. Note 6: Apply K.45 port-to-external port test at the K.20 enhanced level for small telecommunication centers with fewer than 250 lines. |
| Table II. AC tests for ports connected to external symmetric-pair cables. |