Country Frequency Power Flux Density (S) Limit at
950 MHz
Limit at
1850 MHz
International 10–400 MHz 2000 mW/m2 4750 mW/m2 9250 mW/m2
400 MHz to 2 GHz ƒ [MHz] / 0.2 mW/m2
2–40 GHz 10,000 mW/m2
Austria 30–300 MHz 2000 mW/m2 6333 mW/m2 10,000 mW/m2
300 MHz–1.5 GHz 6.66666 x ƒ [MHz] mW/m2
1.5–40 GHz 10,000 mW/m2
Belgium 30–400 MHz 500 mW/m2 1187 mW/m2 2312 mW/m2
400 MHz–2 GHz ƒ [MHz] / 800 W/m2
2–10 GHz 2500 mW/m2
Germany 10–400 MHz 2000 mW/m2 4750 mW/m2 9250 mW/m2
400 MHz–2 GHz ƒ [MHz] / 0.2 mW/m2
2–40 GHz 10,000 mW/m2
Italy 0.1–3 MHz 1000 mW/m2 1000 mW/m2
> 3–3000 MHz 1000 mW/m2
> 3–300 GHz 4000 mW/m2
United States 100–300 MHz 2000 mW/m2 6333 mW/m2 12,333 mW/m2
300 MHz–15 GHz 6.66666 x ƒ [MHz] mW/m2
15–300 GHz 100,000 mW/m2
China 30–300 MHz 2000 mW/m2 6333 mW/m2 10,000 mW/m2
300 MHz–1.5 GHz 6.66666 x ƒ [MHz] mW/m2
1.5–40 GHz 10,000 mW/m2
Japan 30–300 MHz 2000 mW/m2 6333 mW/m2 10,000 mW/m2
300 MHz–1.5 GHz 6.66666 x ƒ [MHz] mW/m2
1.5–40 GHz 10,000 mW/m2
The Netherlands1 10–400 MHz 28 V/m 6920 mW/m2 18,069 mW/m2
400 MHz–2 GHz 53 x ƒ [GHz] 0.72
2–10 GHz 87 V/m
1. Limits given for field strength only.

Table II. Power flux density limits from various standards. Limits are shown for 950 MHz and 1850 MHz.