EMI/RFI Receiver

The NM-7/60A is an EMI/RFI receiver suitable for compliance testing to worldwide industry standards such as FCC, CISPR, EN, VCCI, VDE, and MIL-STD. The unit offers DSP-controlled measurement functions that automate and speed conformance testing. The built-in personal computer with a floppy drive, hard drive, and color flat-panel display provides complete test setup and data analysis. The modem allows for remote operation and diagnostics. The receiver has a frequency range of from 20 Hz to 3.0 GHz. Carnel Labs, Canoga Park, CA; tel: 818-882-3977; fax: 818-882-3981; e-mail: carnel2@pacbell.net.

EMI Coatings

A family of electromagnetic interference (EMI) coatings includes thin-film copper, general-purpose copper, thin-film silver, water-based copper, and water-based silver coatings. Electrodag conductive coatings are suitable for protecting enclosed electronic devices against radiated EMI and electrostatic discharge. The coatings are formulated using various conductive pigments to help comply with emissions regulations worldwide. A coating selection guide is available. The ISO 9001 manufacturing facilities are globally located to meet just-in-time delivery needs. Acheson Colloids Co., Port Huron, MI; tel: 800-255-1908; fax: 810-984-1446; e-mail: web.mail @nstarch.com; Internet: http://www. achesonindustries.com.

Hipot Testers

The 2900-series of UL- and TÜV-listed hipot testers consists of three models. Model 2925 is a 12-mA, 5-kV ac hipot tester. Model 2935 is a 12-mA, 5-kV ac and 5-mA, 6-kV dc hipot tester. Model 2945 offers 12-mA, 5-kV ac hipot; 5-mA, 6-kV dc hipot; and insulation resistance testing. All models in the series feature microprocessor control, a liquid-crystal display, electronic ramp and dwell, test setup memories, and remote control. Slaughter Company, Inc., Lake Forest, IL; tel: 800-504-0055; fax: 847-932-3665; e-mail: info@hipot.com; Internet: http://www.hipot.com.

Drawn Can Shields

Drawn can board-level shields offer seamless corners for increased attenuation. The cans provide additional near-field and far-field circuit isolation at higher frequencies. The small trace sizes preserve packaging space on the printed circuit board. Unlimited configurations for ventilation holes can be incorporated in the design. Tape-and-reel packaging is available. Formed partitions provide multicompartment shielding of components. Mold-in-place and form-in-place elastomer technologies can be combined with drawn cans to shield multiple components with a single part. Laird Technologies, Delaware Water Gap, PA; tel: 570-424-8510; fax: 570-420-6213; e-mail: sales@lairdtech.com; Internet: http:// www.lairdtech.com.

Set Analysis Service

The set analysis service examines designs that use tantalum and aluminum electrolytic capacitors and helps customers select replacement multilayer ceramic capacitors (MLCCs). The basic procedure begins with characterizing the circuit board and taking a complete inventory from the bill of materials, as well as verification of capacitance, actual operating voltage, and other critical parameters. Once the targeted capacitors are identified, analysis is performed on one component. The original capacitor is then replaced with an MLCC, and the performance is measured. Several MLCC values will be tested to find the capacitance value that offers the best performance and cost-effectiveness. TDK Corp. of America, Mount Prospect, IL; tel: 847-803-6100; fax: 847-803-6296; Internet: http://www.component.tdk.com.

EMC Precompliance System

EMI AutoMeasure is a complete automated test system for engineers conducting EMC precompliance tests. The system includes EMITest for NI TestStand software, a radio-frequency (RF) signal analyzer software driver, a National Instruments PXI-5660 RF signal analyzer, a PXI embedded controller or desktop PC, a Sunol Sciences antenna (30 MHz to 2 GHz), and a Panashield compact absorber-lined chamber. Measurement data can automatically be collected from the signal analyzer for an immediate display of pass-or-fail data, as well as the results of underspecification and overspecification. CKC Laboratories Inc., Mariposa, CA; tel: 800-500-4362; fax: 209-742-6133; Internet: http://www.ckc.com.

EMI/RFI Shielding

DiamondBack EMI/RFI shielding features a textured contact surface that increases attenuation at frequencies of 2.45 GHz and greater. The surface consists of hundreds of raised dimples that enhance the conductivity between the gasket and the mating surface. The texturing can be applied to most standard profiles to achieve up to 20 dB of attenuation improvement at high frequencies without increasing the compression force. It is available with numerous mounting and finish options. Tech-Etch Inc., Plymouth, MA; tel: 508-747-0300; fax: 508-746-9639; e-mail: sales@tech-etch.com; Internet: http://www.tech-etch.com.

Safety Compliance Testers

The Omnia series of electrical safety testers have passed the specifications called out in UL 3111. The cUL mark indicates certification for both U.S. and Canadian markets. The multifunction compliance analyzers consist of three models. The 8004 includes ac and dc dielectric withstand testing, insulation resistance testing, ground bond testing, and an optional built-in four-port scanner. The Omnia 5 adds functional run testing, and the Omnia 6 adds line leakage testing. Associated Research, Lake Forest, IL; tel: 800-858-8378; fax: 847-367-4080; e-mail: info@asresearch. com; Internet: http://www.asresearch.com.

Benchtop Chamber

The MicroClimate test chamber is a 1.2-cu-ft benchtop chamber for testing small components and products for a variety of industries. The chamber simulates a full range of temperature conditions from –73° to 190°C. Standard features include a programmable controller, an RS-232 computer interface, and a 2-in. access port. The units are stackable, saving floor space. No special electrical connections are needed, and each chamber runs on a standard 115-V, 15-A circuit. Cincinnati Sub-Zero, Cincinnati, OH; tel: 800-989-7373; e-mail: indsales@cszinc.com; Internet: http://www.cszinc.com.

Continuity Tester

The OS-32 is a self-contained automated continuity test system that verifies the integrity of integrated circuit package bond wires, bare and assembled printed circuit boards, and short cable assemblies. The high-throughput tester is suitable for production testing, incoming inspection, and design verification, as well as for rework and repair stations. The unit offers 16-bit accuracy on both the source and measurement. A fast test speed of 1 millisecond per pin provides immediate feedback on process errors. ProductionLine Testers Inc., Pleasanton, CA; tel: 925-931-1255; fax: 925-931-1256; e-mail: rdamon@ productionlinetesters.com; Internet: http://www.productionlinetesters.com.

BNC Jack Adapters

The recessed housing for the BNC jack offers ample access space around the adapter in a flush-mount package. The unit prevents the jack port from creating a dangerous protrusion capable of causing harm to users or the jack itself. The plastic socket housing provides full electrical isolation from the panel. Trompeter Electronics, Westlake Village, CA; tel: 800-982-2629; fax: 818-706-1040; Internet: http://www. trompeter.com.

ESD Tray

ElastoStatMat trays incorporate static-dissipative elastomer material into the tray to protect printed circuit boards and assemblies against static charge. The electrostatic discharge (ESD) tray can eliminate the need for tape, glue, adhesive, or separate rubber mats. The tray meets or exceeds ANSI/ESD S20.20 standards. The operating temperature ranges from –40° to 200°F, and the static load is greater than 200 lb. The tray can be washed down in normal solvents and soaps without losing ESD properties. Molded Fiber Glass Tray Co., Linesville, PA; tel: 800-458-6050; fax: 814-683-4504; e-mail: info@mfgtray.com; Internet: http://www.mfgtray.com.

Integrated Synthesizer

The AD9858 is an integrated synthesizer that features a 10-bit digital-to-analog convertor, fast frequency hopping, and fine-tuning resolution functionalities. In wireless base stations, the device provides a platform for synthesizers that do not require isolation switches. On-chip functional blocks include a direct digital synthesizer core, a 150-MHz phase detector, a 2-GHz radio-frequency mixer, and a programmable charge pump with proprietary fast-locking acquisition logic. The device can be programmed to operate in a frequency-sweeping or single-tone mode. Analog Devices Inc., Wilmington, MA; tel: 800-262-5643; fax: 781-937-1021; Internet: http://www.analog.com.

Lightning Protectors

The QSS 7-16 series of waterproof lightning protectors offers narrowband capabilities from 0.3 to 3.5 GHz and wideband capabilities from 0.82 to 2.2 GHz. The high-power radio-frequency (RF) units are suitable for protecting base stations and other RF transmit antennas or cable entries for telecommunications and commercial bands such as 3G, PCS, GSM, TETRA, and UMTS. The devices use quarter-wave stub technology. Male and female connector versions are available. NexTek Inc., Westford, MA; tel: 978-486-0582; fax: 978-486-0583; e-mail: nextek@nexteklightning.com; Internet: http://www.nexteklightning.com.

Fast Ethernet Switch

The XL-ES24 is a CompactPCI fast Ethernet switch suitable for telecom and datacom applications, and is suited for manufacturers developing next-generation Internet and voice communications networks. The unit provides 22 10/100-Mb/sec Ethernet ports for PICMG 2.16–compliant in-chassis switching duties to the midplane connectors. Layer 2 switching functions include two front-panel 10/100 RJ-45 ports and two gigabit Ethernet ports. The switch provides an autonegotiation function for 10M/100M or 100M/ 1000M speed, full and half duplex, and flow control. Kontron America, San Diego, CA; tel: 858-677-0877; fax: 858-677-0895; e-mail: sales@us.kontron.com; Internet: http://www.kontron.com.

Capacitive Switch

The CSE15 uG is a capacitive switch with no mechanical parts. The switch is actuated by touch or by approaching the surface where it is mounted. The sensitivity is adjustable to where it is possible to operate the switch behind an overlay up to 20 mm thick, even when the operator is wearing gloves. Any nonconductive material, such as glass, plastic, wood, and ceramic, may be used as a base for the overlay. The switch comes with point illumination in several colors. Schurter Inc., Santa Rosa, CA; tel: 707-636-3000; fax: 707-636-3033; e-mail: info@schurterinc.com; Internet: http://www.schurterinc.com.

EMI Adapters

Fiber-optic EMI shielding adapters can limit EMI emissions from front-panel equipment. The adapters increase shielding effectiveness to greater than –50 dB at 4 GHz. The patented shutter system provides dust protection and eye safety features. The adapters are constructed of die-cast bodies with an EMI gasket that seals the adapter to the panel. Applications include telecommunications and data communications front panels, as well as test equipment. A straight and a 45° mounting orientation are available. Molex Inc., Lisle, IL; tel: 630-512-8787; fax: 630-512-8627; Internet: http://www.molex.com/fiber.

Test Point Loops

Insulated test points are available in eight colors, allowing for color coding and improved product documentation. The through-hole test points are available with 1.02- or 1.32-mm-diam holes. Colored glass insulators and phosphor bronze spring clips provide a working temperature of up to 475°C and resist damage by contact from hot components or soldering irons. A solder-tinned finish and a looped top enable secure attachment to the printed circuit board and easy pickup by scope probes. E-Mark Inc., Shelton, CT; tel: 800-831-5383; fax: 203-922-8231; e-mail: sales@e-markinc.com; Internet: http://www.e-markinc.com

Surge-Arrester Gas Tubes

Surge-arrester gas tubes are suitable for protecting telecom and datacom equipment against lightning surges and electrical transients. The surface-mount devices are nonradioactive and compact in size. The BA model is a two-element device, whereas the BM model is a three-element device. Citel, Miami, FL; tel: 305-621-0022; fax: 305-621-0766; e-mail: citel4u@ix.netcom.com; Internet: http://www.citelprotection.com.